• Send Us a Message
  • Free Shipping Over $90 On Most Orders

    Menu
    Cart 0

    Gigahertz-Optik X1 Series Radiometer - UVC 250-300nm

    Please contact us for a quote on this item.


    Ultraviolet germicidal irradiation (UVGI) is a sterilization method that uses short wavelength light in the UV-C region (100 nm to 400 nm) to break down microorganisms such as viruses, bacteria, yeasts and fungi. The maximum effectiveness for germicidal activity is around 265 nm. The DNA and RNA of microorganisms absorbs the UV-C radiation, which causes changes in their structure rendering them unable to replicate. Microorganisms can be destroyed in a very short time if exposed to sufficiently high intensity UV-C radiation.

    To ensure the germicidal effect, the UV dose must be checked. This is achieved by measuring the UV irradiance at the location of exposure using a UV radiometer.

    In addition to checking the desired germicidal effect of high intensity UV radiation, the potential risk to skin and eyes from relatively low UV intensity must also be determined if there is the possibility of human exposure to the UV radiation. Carrying out both measurements with one device requires UV radiometers with a very large dynamic range.

    The UV-3726 model offers all the properties and features of the UV-37 series detectors. They are specially designed for radiometric measurement tasks in the UV spectral region and have been proven in industrial and scientific use over many years.

    The UV-3726 detector incorporates a photodiode that is only sensitive in the short-wave spectral range. In conjunction with additional optical filtering, only radiation in the specified spectral sensitivity range is measured. This combination enables the radiometric measurement of UV-C LEDs (Figure 2) and low-pressure mercury lamps (Figure 3). Selectable calibration factors for common UV LED wavelengths and low-pressure Hg lamps increase the measuring accuracy.

    To measure the irradiance, the detector's entrance optic is a diffuser with a cosine field of view, which must be positioned in the desired plane of measurement. The diffuser, optical correction filter and photodiode are pre-aged with UV radiation to significantly reduce the inevitable aging process that results from exposure to UV radiation. The UV-3726 detector shows very little aging effects even in intensive use. Any changes are recorded and corrected as part of the recommended annual recalibration.

    The photodiode of the UV-3726 detector offers a strictly linear relationship between the measurement signal and the irradiance in the range from a few pico amps (10-12 A) to several micro amps (10-6 A). When connected to the Gigahertz-Optik X1 meter (Figure 1) it provides a linear measurement range up to at least 1000 mW / cm2 with a resolution of 0.001 µW / cm2.

    Calibration

    Reliable measurements in absolute units require the calibration of the measuring device with traceability to national metrological institute (NMI) standards. Since 1993, the Gigahertz-Optik measuring laboratory has been accredited as a calibration laboratory by the PTB (Physikalisch-Technische Bundesanstalt) and the DAkkS (German Accreditation Body) for the measurement of spectral responsivity and spectral irradiance. Since then, all factory calibrations have been closely based on the calibration standards and quality management of the accredited calibration laboratory. Therefore, the factory calibrations of Gigahertz-Optik offer the highest possible level of traceability and have been accepted worldwide for many years.

    In accordance with the requirements of individual industrial sectors, part of the measuring laboratory is accredited by the DAkkS as a DIN EN ISO / IEC 17025 test laboratory. As a result, Gigahertz-Optik can optionally offer a DIN EN ISO / IEC 17025 test certificate for the UV radiometer X1 with UV-3726 in addition to the factory certificate.

    The UV-3726 detector is calibrated for its spectral responsivity. When performing a measurement, the nominal wavelength of the UV-LED or Hg lamp can be selected on the X1 meter for highest precision. The meter offers several calibration options:

    • An average calibration factor for measuring any UV LEDs in the spectral range from 260 nm to 290 nm.
    • A specific calibration factor for measuring low-pressure Hg lamps (at 254nm).
    • Eleven, wavelength dependent, calibration factors given in 5 nm increments from 250 to 300 nm for measuring UV LEDs with known nominal wavelength.

    Measuring device X1

    The X1 measuring device evaluates the signal from the UV-3726 detector and displays the measured irradiance in absolute units, mW / cm2. The high-quality signal amplifier of the meter supports the very large dynamic range of the detector and thus offers a measuring range of up to 1000 mW / cm2 with a resolution of 0.001 µW / cm2. In addition to the irradiance, the dose can also be displayed in J / cm2. The measuring device offers a ‘peak-hold' display function. The ergonomic housing of the device with its two AA batteries supports mobile use. Alternatively, the measuring device can be operated via its USB interface with the available application software for PCs. A software development kit (SDK) enables the measurement device to be integrated into user-written software.

    Entrance Optic11 mm ∅ diffuser
    Spectrum250 - 300nm
    TypeUVC / UVGI
    Typical Range (max)1000 mW / cm2
    Typical Range (min)0.002 µW / cm2

    ProLampSales Order Code6191442165960
    BrandGigahertz-Optik
    SeriesX1
    MPNX1-1-UV-3726

    There are currently no videos for this product.

    Optional Parts & Accessories

    Possible Alternative/Equivalent Products

    Shipping Policy

    Expedited Shipping Rates

    For expedited shipping, please contact us for a price quote and cutoff times.

    Continental United States

      • Most Orders Over $90.00 Ship Free
      • Shipping for other orders is calculated at checkout

    Certain restrictions apply, including oversize, heavy objects, and some fixtures/equipment.

    Alaska & Hawaii

    • Shipping calculated at checkout

    US Territories

    • Contact us for a quote.

    International Shipping

    Contact us for a quote. We do not ship most glass bulbs and fixtures internationally. If you have your own UPS/Fedex/DHL account, we may be able to ship using that.

    Shipping to US-Based Freight Forwarders

    For shipments to freight forwarders, we are only responsible for shipping to the freight forwarder directly. Please have your freight forwarder check your items for damage. We are not responsible for shipping damages incurred after the items leave the freight forwarder.


    Business Office Hours

    We can be reached by phone (800-784-1998) weekdays from 7:30am to 5pm Pacific Time.

    Our business office is closed Saturday and Sunday throughout the year, Memorial Day, 4th of July, Labor Day, Thanksgiving day, Christmas day and New Year's day.

    Orders can be placed on the website at anytime - 24/7.

    California Title 20 Notice

    Certain general service lighting products are no longer allowed to be sold in California. We make every attempt to inform you before purchase which items are unable to ship to California. If we discover an item you purchased can not be shipped, we may have to cancel the order. We apologize for any inconvenience this causes. Please contact your state representative for more information.

    California Prop 65

    California Prop 65 WarningWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

    Returns Policy

    Returns are sometimes necessary. Our policy is to provide you with a hassle-free return experience.

    Accepted Returns

    Items Damaged in Shipping

    If the product was damaged during shipping, first keep all packing materials, then call or email us to report the damage. Damage must be reported with 3 days of you receiving the shipment. We will have you return the product using the Returned Material Authorization (RMA) we will provide. We will send you a new product or provide a full refund and we will reimburse you for any shipping charges you may incur.

    Missing Items

    If all the items you ordered are not in the shipment, call us within 3 days of receiving the shipment so we can promptly send the missing item(s).

    Wrong Product Ordered or Product No Longer Needed

    If you ordered the wrong product call or email us so we can help you get the correct product. If the product purchase error was in no way the fault of information provided on ProLampSales.com, you are responsible for the return shipping cost and a 25% re-stocking fee.

    Returns After 30 Days

    Items ordered from ProLampSales can be returned within 30 days of receipt of the shipment in most cases. Please check that all of your items are present and in working condition within this timeframe.

    After 30 days, if the product does not perform to specifications or fails within stated warranty periods, see manufacturer warranty information for procedures to follow.

    Products that Differ from Our General Return Policy

    International Orders

    International orders are non-returnable.

    Gas Detectors & Air Quality Monitors

    For safety reasons, we do not accept returns on gas detectors or air quality monitors. Once these products leave our warehouse, we can not be sure what environments they are used/stored in or what dangerous gases or pollutants they are exposed to.

    Larson Electronics

    Larson Electronics UVC lighting products of any kind are non-returnable. Larson Electronics orders are subject to a minimum 15% cancellation fee. If you need help with a product, please contact us before ordering or verify that you are ordering the correct item.

    Soraa

    Non-Quick Ship Soraa brand products are non-returnable. If an error was made in order fulfillment or shipping, replacements may be sent out or a refund issued.