Osram 69182 HBO 103 W/2 | 100 Watt, Mercury Short Arc, Double-Ended
100 watt, mercury short arc, double-ended
OSRAM HBO Mercury Short Arc Discharge Lamps (≤ 200W) are intense point sources that provide a broad spectrum through the visible and ultraviolet range. These lamps are optimal sources for fiber illumination devices for Medical, Scientific, and various Industrial areas. The broad spectrum makes these lamps ideal for microscopy applications.
Product Features and Benefits
- High luminance / radiance with intense point source
- Broad spectral distribution in the visible and ultraviolet range
- Enhanced UV characteristics available on some types
- High arc stability
Areas of Application
- Microscopy
- Laboratory & Analysis
- UV Curing
- Fiber Illumination
- Microscopy
- Solar Simulation
Safety Advice
Due to their high luminance, UV radiation, and high internal pressure in the hot state, HBO and HXP lamps may only be operated in enclosed lamp casings designed for their operation. Since mercury is released if the lamp breaks, special safety precautions must be taken.
Product Notes
Operating Position = Vertical, base down
Lamp optimized for fluorescence microscopy.
Cross Reference Part Numbers
- OSRAM HBO 100 W/2 0000256 69217
- USHIO USH-103D 0036212 5001329
- USHIO USH-102D 0000293 5000273
Equipment Used In
- OLYMPUS AX70TRF
- OLYMPUS BH-RFL
- OLYMPUS BH2-RFL
- OLYMPUS IMT-2
- OLYMPUS IMT2-RFL
- OLYMPUS IX-RFA
- ZEISS "AXIOPLAN 2 IMAGING FOR EPI-FLUORESCENCE W/ ""APOTOME"" EQUIPME
- ZEISS AXIO EXAMINER.A1
- ZEISS AXIO EXAMINER.D1
- ZEISS AXIO EXAMINER.Z1
- ZEISS AXIO IMAGER.A1
- ZEISS AXIO IMAGER.A1M
- ZEISS AXIO IMAGER.A2
- ZEISS AXIO IMAGER.A2M
- ZEISS AXIO IMAGER.D1
- ZEISS AXIO IMAGER.D1 FOR EPI-FLUORESCENCE W/ APOTOME EQUIPMENT
- ZEISS AXIO IMAGER.D1M
- ZEISS AXIO IMAGER.D2
- ZEISS AXIO IMAGER.D2M
- ZEISS AXIO IMAGER.M1
- ZEISS AXIO IMAGER.M1M
- ZEISS AXIO IMAGER.M2
- ZEISS AXIO IMAGER.M2M
- ZEISS AXIO IMAGER.Z1
- ZEISS AXIO IMAGER.Z1 + APOTOME
- ZEISS AXIO IMAGER.Z1M
- ZEISS AXIO IMAGER.Z2
- ZEISS AXIO IMAGER.Z2M
- ZEISS AXIO OBSERVER.A1
- ZEISS AXIO OBSERVER.A1 ENTRY
- ZEISS AXIO OBSERVER.D1
- ZEISS AXIO OBSERVER.D1 + APOTOME
- ZEISS AXIO OBSERVER.D1 ENTRY
- ZEISS AXIO OBSERVER.D1 MID RANGE
- ZEISS AXIO OBSERVER.Z1
- ZEISS AXIO OBSERVER.Z1 CELL OBSERVER
- ZEISS AXIO OBSERVER.Z1 HIGH END
- ZEISS AXIO OBSERVER.Z1 TIRF 3
- ZEISS AXIO OBSERVER.Z1M ACR
- ZEISS AXIO SCOPE.A1
- ZEISS AXIO SCOPE.A1 POL
- ZEISS AXIO SCOPE.A1 VARIO
- ZEISS AXIOPLAN 2 IMAGING
- ZEISS AXIOPLAN 2 IMAGING E
- ZEISS AXIOPLAN 2 IMAGING MAT
- ZEISS AXIOSKOP 2 FS MOT
- ZEISS AXIOSKOP 2 FS PLUS
- ZEISS AXIOSKOP 2 MAT
- ZEISS AXIOSKOP 2 MAT MOT
- ZEISS AXIOSKOP 2 MOT PLUS
- ZEISS AXIOSKOP 2 PLUS
- ZEISS AXIOSKOP 40
- ZEISS AXIOSKOP 40 A POL
- ZEISS AXIOSKOP 40 FL
- ZEISS AXIOSKOP 40 POL
- ZEISS AXIOTECH VARIO
- ZEISS AXIOVERT 135
- ZEISS AXIOVERT 200
- ZEISS AXIOVERT 200 FOR EPI-FLUORESCENCE W/ APOTOME EQUIPMENT
- ZEISS AXIOVERT 200 M
- ZEISS AXIOVERT 200 M FOR EPI-FLUORESCENCE W/ APOTOME EQUIPMENT
- ZEISS AXIOVERT 200 M MAT
- ZEISS AXIOVERT 200 MAT
- ZEISS PALM MICROBEAM
- ZEISS STEMI SV 11 APO
- ZEISS STEMI SV 6
- ZEISS STEREO DISCOVERY.V12
- ZEISS STEREO LUMAR.V12
- ZEISS MICROSCOPES AXIOLAB/AXIOSKOP/AXIOPLAN/AXIOPHOT,3803019350
About Osram
Osram provides businesses and consumers with a wide portfolio of products, encompassing many types of technical and professional lighting applications. These include automotive lighting, complete "Smart" digital systems, advancted LED chips, speciality light bulbs and fixtures, and more. Osram serves both consumer and professional markets, and manufactures traditional lighting products, as well as LED lamps and luminaires.
Average Luminance (cd/cm2) | 150000 cd/cm2 |
---|---|
Average Rated Life | 300 h |
Base Anode | SFa7.5-2 |
Base Cathode | SFa9-2 |
Bulb Shape | T10 |
Cooling | Convection |
Current (A) | 4.44 A |
Diameter d (in) | 0.394 in |
Electrode Gap - cold (mm) | 0.6 mm |
Lamp Type | HBO103W/2 |
Luminous Area (mm) | 0.25 x 0.25 mm |
Luminous Flux | 2550 lm |
Luminous Intensity (cd) | 270 |
Maximum Base Temperature (C) | 230 C |
Operating Position | s 90 |
Watts | 103 |
ProLampSales Order Code | 4369538023556 |
---|---|
Brand | Osram |
Series | HBO |
MPN | 69182 |
Model | HBO 103 W/2 |
UPC | 4050300382128 |
HS Code | 853941 |
Documents
There are currently no videos for this product.
Optional Parts & Accessories
Alternative Products
Shipping Policy
Expedited Shipping Rates
For expedited shipping, please contact us for a price quote and cutoff times.
Continental United States
- Shipping for most orders is calculated at checkout*
- If you want to ship on your own UPS/Fedex account, please contact us
*Certain restrictions apply, including oversize, heavy objects, and some fixtures/equipment.
For large, heavy, or oversized items, additional shipping charges may apply. The site may not correctly calculate freight shipments at time of order. Large counts of smaller products may also result in additional shipping costs. We apologize for any inconvenience this may cause. Please contact us for an estimate on large items to determine an accurate shipping cost.
Alaska & Hawaii
- Shipping calculated at checkout
US Territories
- Contact us for a quote.
International Shipping
Contact us for a quote. We do not ship most glass bulbs and fixtures internationally. If you have your own UPS/Fedex/DHL account, we may be able to ship using that.
Shipping to US-Based Freight Forwarders
For shipments to freight forwarders, we are only responsible for shipping to the freight forwarder directly. Please have your freight forwarder check your items for damage. We are not responsible for shipping damages incurred at or after the items leave the freight forwarder.
California Title 20 Notice
Certain general service lighting products are no longer allowed to be sold in California. We make every attempt to inform you before purchase which items are unable to ship to California. If we discover an item you purchased can not be shipped, we may have to cancel the order. We apologize for any inconvenience this causes. Please contact your state representative for more information.
California Prop 65
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
Returns Policy
Returns are sometimes necessary. Our policy is to provide you with a hassle-free return experience.
Accepted Returns
Items Damaged in Shipping
If the product was damaged during shipping, first keep all packing materials, then call or email us to report the damage. Damage must be reported with 3 days of you receiving the shipment. We will have you return the product using the Returned Material Authorization (RMA) we will provide. We will send you a new product or provide a full refund and we will reimburse you for any shipping charges you may incur.
Missing Items
If all the items you ordered are not in the shipment, call us within 3 days of receiving the shipment so we can promptly send the missing item(s).
Wrong Product Ordered or Product No Longer Needed
If you ordered the wrong product call or email us so we can help you get the correct product. If the product purchase error was in no way the fault of information provided on ProLampSales.com, you are responsible for the return shipping cost and a 25% re-stocking fee.
30 Day Return Policy
Items ordered from ProLampSales can be returned within 30 days of receipt of the shipment in most cases. Please check that all of your items are present and in working condition within this timeframe.
After 30 days, if the product does not perform to specifications or fails within stated warranty periods, see manufacturer warranty information for procedures to follow.
Products that Differ from Our General Return Policy
International Orders
International orders may be non-returnable. Please contact us before ordering.
Air Quality Monitors
For safety reasons, we do not accept returns onair quality monitors. Once these products leave our warehouse, we can not be sure what environments they are used/stored in or what dangerous gases or pollutants they are exposed to.
Soraa
Non-Quick Ship Soraa brand products may be non-returnable. If returnable, Soraa products may have up to a 40% restocking fee. If an error was made in order fulfillment or shipping, replacements may be sent out or a refund issued.
Categories: Microscope Light Bulbs, Osram, Short Arc Mercury Double Ended